§ 6.24.010. Safety rules and conditions.


Latest version.
  • All business establishments showing films or staging and showing live entertainment to patrons on an individual booth-by-booth, or individual room-by-room, basis shall be subject to the following:

    A.

    All walls, partitions and doors shall be of either noncombustible material or material of not less than one hour fire-resistant time rating.

    B.

    All furniture, furnishings, rugs and carpets shall be of a fabric or material with a flame spread rating of seventy-five or less, according to the ASTME 84 Test.

    C.

    Each room or booth shall have not less than thirty square feet of floor area for each occupant.

    D.

    All aisles shall not be less than fifty inches in width, and no such aisle shall have a dead end.

    E.

    Each room or booth shall have at least two lighted exits within the constant and unobstructed view of the occupant or occupants, which exits shall lead directly to the outside of such business establishment.

    F.

    There shall be no locks on doors in rooms or booths which could prevent a person from entering or leaving such room or booth.

    G.

    All electrical equipment shall be grounded and no electrical receptacles or outlets shall be serviced by extension cords.

    H.

    The light level throughout each booth, room and aisle shall not be less than 1.0 footcandle measured at the floor level. Such lights shall be placed not less than three feet above the floor level.